Cable Failure Analysis...

3U was contracted to review the factors associated with the electrical and optical degradation of a working opto-electromechanical cable used for supplying power and signals to a remotely operated vehicle. 3U observed the dissection of the cable by Customer technicians, reviewed the working gear used with the cable, and reviewed the operational procedures used for deployment and recovery of the cable. Based on these observations, recommendations were made for improvements that could be made to the system and procedures that would improve the service life of the cable.